Merhabalar..
Roland XC-540 da sorunum var service call 0110 ne sorunu ola bilir acaba ?
İÇERİK:
Input value from Linear
Encoder is not changed
when Linear Encoder is
setup the origin.
When Motor stops during
printing, Motor does not
complete the movement
which is supposed to be
done.
NEDEN:
Read error of Linear Encoder.
Read error of Encoder on Scan Motor side.
Wire is not fixed to Head Carriage firmly.
EYLEM:
Confirm whether Encoder Scale is between the slit of Encoder Module
in a whole width of the machine
Check Cable connection between Linear Encoder Board and Print
Carriage Board
Confirm connection between Wire and Head Carriage
Linear Encoder replacement
Scan Motor replacement
Main Board replacement
UMARIM İNGİLİZCEN VARDIR...